VAT rates and annual servicing in Ireland
A single supply-and-install contract for a qualifying low-emission air-to-water heat pump (including controls, radiators, underfloor loops and pipework in that contract) carries 9% VAT in Ireland since 1 January 2025. Standalone radiator or cylinder jobs, separate installation contracts and annual servicing carry 13.5% VAT, while supply-only equipment carries 23%. An annual air-to-water service in Ireland typically costs €180 to €280 and keeps manufacturer warranties valid.
How Revenue's 9% supply-and-install heat pump VAT rule saves hundreds over 13.5% or 23%, and what a €180 to €280 yearly service checks.
Free, no obligation. One local installer prices it, not five.
- 9% VATsingle supply-and-install contract
- 13.5% VATstandalone rads, labour & servicing
- 23% VATsupply-only hardware purchases
- €180–€280typical annual service cost

Revenue VAT bands for air-to-water projects
Under Finance Act 2024 and Revenue's Tax and Duty Manual on heat pump heating systems, the VAT rate dropped from the reduced rate to the second reduced rate of 9% from 1 January 2025 for qualifying supply-and-install contracts:
Single supply-and-install heat pump contract
- Irish VAT rate
- 9% VAT
- What it covers
- Outdoor unit, indoor controls, cylinder, radiators, underfloor emitters and pipework supplied and installed by the same business.
Standalone radiator, cylinder or servicing work
- Irish VAT rate
- 13.5% VAT
- What it covers
- Separate installation-only contracts, standalone emitter/cylinder jobs (subject to two-thirds rule) and annual maintenance visits.
Supply-only hardware purchase
- Irish VAT rate
- 23% VAT
- What it covers
- Buying a heat pump unit, stainless cylinder or manifold separately without an installation contract.
On a €15,000 net supply-and-install job, contracting under one business at 9% VAT saves €675 compared with 13.5% VAT and €2,100 compared with buying equipment at 23% VAT.
Price my air-to-water system
Four quick taps and you see the full cost and net after the €6,500 SEAI grant before any phone number is asked for. One local installer rings you, not five.
3-bed semi or terrace (6 to 8 kW), radiators (with K2/K3 swaps), SEAI grant: €12,800 to €18,000 full (€6,300 to €11,500 after €6,500 grant).
How the price is worked out
The range reflects typical Irish supply-and-install air-to-water hydronic heat pump packages at 9% VAT: outdoor monobloc or split unit, indoor controls, a 200 L to 300 L heat-pump hot water cylinder, core pipework, emitter allowance and commissioning. Where SEAI grant applies to a pre-2021 house, we deduct the €6,500 base Heat Pump System grant to give a conservative net figure; qualifying oil or gas boiler swaps can also claim up to €2,000 for central heating upgrades and a €4,000 Renewable Heat Bonus under SEAI rules. Attic or wall insulation upgrades, ESB 16 kVA supply upgrades (€2,245) and floor screed are separate. airtowaterheating.ie is not SEAI or a government body and does not award grants. Only a room-by-room heat-loss survey gives a firm quote.
What an annual €180 to €280 air-to-water service covers
- Magnetic filter and Y-strainer clean. Clears magnetite particles and debris that restrict primary water flow and wear circulating pumps.
- Glycol strength and inhibitor check. Tests frost-protection concentration (on glycol monoblocs) and corrosion inhibitor levels so steel radiators stay rust-free.
- Outdoor coil wash and condensate check. Cleans leaves, pollen and cobwebs off evaporator fins and confirms the defrost drain flows freely.
- Expansion vessel and pressure check. Verifies system cold fill pressure (typically 1.2 to 1.5 bar) and recharges vessel air cushions.
- Electrical terminals, defrost & fault log. Inspects isolator tightness, checks compressor run hours and start-stop counts, and tests defrost and Legionella schedules.
- F-Gas leak record (where applicable). Certifies refrigerant pressures and logs annual service dates to protect 5- to 7-year manufacturer warranties.
Related air-to-water guides
Air-to-water costs IrelandFull 2026 Irish price breakdown by house type, emitters, cylinder and SEAI grant.
New-build air-to-water systemsFirst-fix UFH manifolds, airtightness, Part L compliance and 9% supply-and-fit VAT.
Monobloc vs split heat pumpsR290 sealed monobloc units versus split systems, flow temperature and frost care.
Hot water cylinders and Legionella200 L vs 300 L stainless cylinders, large coil surface area and 60 °C weekly cycles.
Outdoor placement and 43 dB rulesClass 2(d) S.I. No. 342 of 2026 rules, 43 dB(A) neighbour limits and condensate drains.
SEAI €6,500 grant and HLI rulesBase €6,500 grant, fossil-fuel bonus package up to €12,500, €200 TA and HLI rules.Common questions before switching
Does the 9% VAT rate apply to new-build heat pumps as well as retrofits?
Yes. Revenue's manual confirms the 9% supply-and-install rate applies regardless of property type, covering both new builds and existing home retrofits when supplied and installed under one contract.
What happens if I buy radiators myself at a builder's merchant?
Supply-only radiators carry 23% VAT. Having your heat pump installer supply and fit them inside the single supply-and-install heat pump contract keeps them at 9% VAT.
Do I void my warranty if I skip annual servicing?
Almost all heat pump manufacturers make an annual logged service by a qualified engineer a strict condition of their extended 3- to 7-year parts warranties.
Can I clean anything myself between annual services?
Yes. Keep fallen leaves, grass clippings and snow clear of the outdoor unit's rear intake grille and front fan discharge, and never stack bins or timber against the casing.
All air-to-water heating pages and guides
Heating setups
Technical guides

See your air-to-water price before anyone rings