Heat-pump hot water cylinders and Legionella cycles
An air-to-water heat pump requires a dedicated 200 L to 300 L unvented stainless-steel cylinder with a 2.5 m² to 3.5 m² internal coil (roughly four times larger than an old boiler cylinder coil). Tanks run daily at 48 °C to 52 °C on the compressor and run a weekly 60 °C Legionella cycle for one hour.
Why an ordinary copper tank fails on a heat pump, sizing 200 L versus 300 L unvented stainless tanks, coil area and weekly pasteurisation.
Free, no obligation. One local installer prices it, not five.
- 200–300 Ltypical Irish cylinder capacity
- 2.5–3.5 m²required heat-exchanger coil area
- 50 °C / 60 °Cdaily store / weekly Legionella
- €1,000–€1,400200 L tank supply cost

Sizing cylinder volume and coil surface area
1 to 2 people, 1–2 bathrooms
- Recommended tank
- 180 L to 200 L
- Minimum coil area
- 2.0 to 2.5 m²
- Supply cost (tank only)
- €1,000 to €1,400
3 to 4 people, 2–3 bathrooms
- Recommended tank
- 250 L
- Minimum coil area
- 2.5 to 3.0 m²
- Supply cost (tank only)
- €1,100 to €1,500
4 to 6 people, 3+ showers or baths
- Recommended tank
- 300 L
- Minimum coil area
- 3.0 to 3.5 m²
- Supply cost (tank only)
- €1,200 to €1,700
Solar thermal / PV diverter add-on
- Recommended tank
- 250 L to 300 L twin-coil / immersion
- Minimum coil area
- 3.0 m² primary + PV immersion
- Supply cost (tank only)
- €1,350 to €1,900
A standard 140 L green foam-lagged copper cylinder has a tiny 0.5 m² coil that can transfer barely 3 kW of heat when fed with 55 °C flow water, causing the heat pump to trip on high-pressure fault. Corrugated stainless heat-pump coils transfer 10 kW to 15 kW smoothly, reheating 250 litres from cold in 40 to 60 minutes.
Price my air-to-water system
Four quick taps and you see the full cost and net after the €6,500 SEAI grant before any phone number is asked for. One local installer rings you, not five.
4-bed detached house (9 to 12 kW), radiators (with K2/K3 swaps), SEAI grant: €15,300 to €21,000 full (€8,800 to €14,500 after €6,500 grant).
How the price is worked out
The range reflects typical Irish supply-and-install air-to-water hydronic heat pump packages at 9% VAT: outdoor monobloc or split unit, indoor controls, a 200 L to 300 L heat-pump hot water cylinder, core pipework, emitter allowance and commissioning. Where SEAI grant applies to a pre-2021 house, we deduct the €6,500 base Heat Pump System grant to give a conservative net figure; qualifying oil or gas boiler swaps can also claim up to €2,000 for central heating upgrades and a €4,000 Renewable Heat Bonus under SEAI rules. Attic or wall insulation upgrades, ESB 16 kVA supply upgrades (€2,245) and floor screed are separate. airtowaterheating.ie is not SEAI or a government body and does not award grants. Only a room-by-room heat-loss survey gives a firm quote.
Daily water temperature, Legionella cycles and shower pressure
- Store daily water at 48 °C to 52 °C. Higher daily targets crush hot-water COP; 50 °C delivers plenty of scalding-safe shower mix when the cylinder is generously sized.
- Weekly 60 °C Legionella pasteurisation. SEAI DTSS v4.0 requires the cylinder to reach at least 60 °C and hold it for at least one full hour once a week, usually scheduled during a cheap Sunday night electricity slot.
- Mains-pressure unvented performance. Pressurised stainless cylinders feed strong thermostatic mixer showers across every bathroom without noisy attic booster pumps, provided cold mains pressure is healthy (or paired with a cold-water booster set).
- Schedule hot water outside 5 pm to 7 pm peak. Program one main reheat at 2 am to 5 am on cheap night electricity, plus an optional afternoon top-up if teenagers take back-to-back showers.
Related air-to-water guides
Day/night and smart tariffs24-hour, NightSaver and EV smart plans to shift water heating into cheap night hours.
Replacing a gas boilerCutting gas standing charges, planning cylinder space and sizing low-temp radiators.
Bungalow and detached retrofits12 to 16 kW sizing, roof and cavity insulation first, and ESB 16 kVA supply checks.
New-build air-to-water systemsFirst-fix UFH manifolds, airtightness, Part L compliance and 9% supply-and-fit VAT.
VAT rates and annual servicing9% supply-and-install VAT, 13.5% standalone work and €180 to €280 yearly servicing.
Air-to-water costs IrelandFull 2026 Irish price breakdown by house type, emitters, cylinder and SEAI grant.Common questions before switching
Will a 250 L heat-pump cylinder fit in my existing Irish hot press?
A standard 250 L cylinder measures roughly 550 mm to 595 mm in diameter and 1,500 mm to 1,700 mm tall (300 L sits near 1,800 mm tall). Check doorway width and shelf framing during the installer's survey.
Can I keep using an electric shower alongside a heat-pump cylinder?
Yes, though switching to a thermostatic mixer shower fed from the pressurised cylinder uses three times less electricity per shower and frees up 9 kW of peak electrical demand on your fuse board.
Does the immersion heater run every day on a heat pump?
No. The outdoor heat pump handles daily 50 °C water heating at a COP of 2.5 to 3.2; the backup electric immersion only assists the brief weekly 60 °C Legionella sterilisation cycle on lower-temp units.
What does standing heat loss cost on a modern heat-pump cylinder?
Factory-injected 50 mm to 60 mm polyurethane foam keeps standby heat loss near 1.2 to 1.8 kWh a day, costing roughly 15 c to 20 c daily.