Air-to-water heating with radiators

You do not need underfloor heating to fit an air-to-water heat pump. Most Irish retrofits keep the existing 15 mm and 22 mm central heating pipework and swap only the undersized single-panel radiators to K2 double or K3 triple convectors, adding €800 to €2,800 to a system quote.

Running wet radiators at 40 °C to 45 °C instead of 70 °C, which rooms need K2 or K3 swaps, and what stays untouched.

Free, no obligation. One local installer prices it, not five.

  • 40–45 °Ctarget radiator flow temperature
  • €280–€550fitted K2/K3 radiator swap
  • 3.4–3.8typical seasonal SCOP on rads
  • €800–€2,800whole-house rad upgrade budget
A white steel panel convector radiator fitted on an interior painted wall

Why radiators feel warm rather than scorching hot

An oil or gas boiler pushes 65 °C to 75 °C water into small single-panel radiators for two hours in the morning and four hours at night. An air-to-water heat pump works gently all day using 40 °C to 45 °C water. Because the radiator surface is cooler to the touch, each room needs more metal fin area to release the same wattage of steady heat into the air.

Traditional 70 °C oil/gas boiler

Flow water temperature
65 °C to 75 °C
Temperature drop (Delta T)
15 °C to 20 °C across radiator
Typical panel type
Single panel (K1 / Type 11)
Daily running pattern
Short blasts on morning/evening timer

Low-temp 42 °C air-to-water

Flow water temperature
40 °C to 45 °C (weather compensated)
Temperature drop (Delta T)
5 °C across radiator
Typical panel type
Double (K2 / Type 22) or triple (K3 / Type 33)
Daily running pattern
Steady continuous output with gentle setback

Price my air-to-water system

Four quick taps and you see the full cost and net after the €6,500 SEAI grant before any phone number is asked for. One local installer rings you, not five.

3-bed semi or terrace (6 to 8 kW), radiators (with K2/K3 swaps), SEAI grant: €12,800 to €18,000 full (€6,300 to €11,500 after €6,500 grant).

Step 1 of 5

What kind of house is it?

Pick the closest match. The installer checks room heat loss on site.

How the price is worked out

The range reflects typical Irish supply-and-install air-to-water hydronic heat pump packages at 9% VAT: outdoor monobloc or split unit, indoor controls, a 200 L to 300 L heat-pump hot water cylinder, core pipework, emitter allowance and commissioning. Where SEAI grant applies to a pre-2021 house, we deduct the €6,500 base Heat Pump System grant to give a conservative net figure; qualifying oil or gas boiler swaps can also claim up to €2,000 for central heating upgrades and a €4,000 Renewable Heat Bonus under SEAI rules. Attic or wall insulation upgrades, ESB 16 kVA supply upgrades (€2,245) and floor screed are separate. airtowaterheating.ie is not SEAI or a government body and does not award grants. Only a room-by-room heat-loss survey gives a firm quote.

Which rooms usually need bigger radiators

  • Living rooms and north-facing bedrooms. High glazing area or two external walls make these the first rooms to swap from K1 to K2 or K3.
  • Hallways and landings. A single small hallway radiator often pulls heat up the stairwell; upsizing it stops downstairs feeling draughty.
  • Bathrooms and en-suites. Small chrome towel rails put out very little heat at 42 °C; pair a towel rail with a compact K2 panel or electric dual-fuel element.
  • Existing pipe bore check. Sound 15 mm copper or PEX drops feed most domestic radiators cleanly, while very old 8 mm or 10 mm microbore may restrict the higher flow rate a heat pump needs.

For exact EN 442 output factors and Delta T sizing maths, see sizing K2 and K3 radiators for heat pumps.

Common questions before switching

Do all radiators have to be replaced for air-to-water heating?

No. Houses built in the 2000s often already have K2 double convectors in several rooms. A room-by-room heat-loss survey identifies the exact rooms that fall short at 45 °C flow.

Can I keep decorative cast-iron or vertical designer radiators?

Only if their certified output at Delta T 20 K (45 °C flow) covers the room's heat loss. Many narrow vertical panels lose more than 65% of their brochure wattage when run on a heat pump.

Should I keep thermostatic radiator valves (TRVs) open?

Keep TRVs fully open in main living zones controlled by the room thermostat, and use TRVs only to trim sunny south-facing rooms or spare bedrooms. Closing too many TRVs starves the pump of water flow.

What does SEAI pay towards radiator upgrades?

Eligible pre-2021 houses can claim up to €2,000 under SEAI's central heating upgrade grant alongside the €6,500 base heat pump grant. airtowaterheating.ie is not SEAI or a government body and does not award grants.

All air-to-water heating pages and guides

An outdoor air-to-water heat pump unit on a plinth beside a red-brick wall and garden shrubs

See your air-to-water price before anyone rings

Pick your house size, radiators or underfloor heating and SEAI grant route. When you want a room-by-room heat-loss quote, your outline goes to a single local heating installer in your county.